These RF detectors are designed to convert an RF input signal to a DC output signal. Model series 852-246-XXX* are 50 Ohm RF detectors that operate from 1 to 3000 MHz. Input power is 100 mW maximum, VSWR is 1.40:1 maximum and flatness is ± 0.5 dB maximum. The RF input connector is N male while the DC output connector is BNC female. These units are available in positive or negative output DC polarity and the operating temperature range is -55°C to +100°C. Other connector types and 75 Ohm RF detectors are also available. Please contact us with your unique requirement for the appropriate model number.
*Insert desired output DC polarity (example POS = positive / NEG = negative)